Magnetic-inductive flow meter

SMF620

Option name 1
āļˆāļģāļ™āļ§āļ™
āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļŠāļīāļ™āļ„āđ‰āļē

āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī

Product characteristics
Measuring range                 30...3000 l/min       1800...180000 l/h      0.1...10 m/s      1.8...180 mÂģ/h
Nominal diameter                DN80 (3)
Process connection              ifm-specific device flange

Application
Special feature                   Gold-plated contacts
Application                        food and beverage industry
Media                               conductive liquids; water; hydrous media
Note on media                   food products such as beer, milk, fruit juices, soft drinks, ketchup, yoghurt, yoghurt toppings, ice cream
                                       conductivity: 5 ÂĩS/cm
Medium temperature [°C]      -20...150
Min. bursting pressure          37.5 bar              3.75 MPa
Pressure rating                    25 bar               2.5 MPa

Electrical data
Operating voltage [V]          18...32 DC
Current consumption [mA]    250; (24V)
Protection class                  III
Reverse polarity protection   yes
Power-on delay time [s]        < 5

Measuring principle
magnetic-inductive              Inputs / outputs
Total number of inputs and outputs    2

Inputs
Inputs                               OUT2                external totaliser reset

Outputs
Total number of outputs       2
Output signal                     OUT1                 pulse signal; totaliser switching signal; diagnostic signal; IO-Link
                                      OUT2                 analogue signal; pulse signal; totaliser switching signal; diagnostic signal
Electrical design                 PNP/NPN
Pulse output                      flow rate meter
Short-circuit protection        yes
Type of short-circuit protection     pulsed
Overload protection            yes

Analogue
Number of analogue outputs      1
Analogue current output [mA]    4...20; (skalierbar)
Max. load [ÎĐ]                           500
Resolution of analogue output    0.38 ÂĩA

Digital
Number of digital outputs          2
Max. voltage drop switching output DC [V]                    2
Permanent current rating of switching output DC [mA]     100
Switching frequency DC [Hz]      0...10000

Measuring/setting range
Measuring range                  30...3000 l/min       1800...180000 l/h       0.1...10 m/s     1.8...180 mÂģ/h
Display range                     -3600...3600 l/min   -216000...216000 l/h   -12...12 m/s    -216...216 mÂģ/h
Resolution                           0.1 l/min               200 l/h                    0.01 m/s       0.2 mÂģ/h
Note on factory setting          0...45,0 mÂģ/h
Analogue start point ASP        0...2400 l/min        0...144000 l/h            0...7.95 m/s    0...144 mÂģ/h
Analogue end point AEP        600...3000 l/min     36000...180000 l/h     2...9.95 m/s    36...180 mÂģ/h
Low flow cut-off LFC              0...2400 l/min        0...144000 l/h            0...7.95 m/s    0...144 mÂģ/h
Pulse length [s]                     0.002...2
Pulse value                          0.005...99990000 I

Temperature monitoring
Measuring range [°C]            -20...150
Display range [°C]                -20...150
Resolution [°C]                     0.01
Analogue start point [°C]      -20...116
Analogue end point [°C]        14...150

Conductivity monitoring
Measuring range [ÂĩS/cm]          100...100000
Display range [ÂĩS/cm]              0...10000000
Resolution [ÂĩS/cm]                   1
Analogue start point [ÂĩS/cm]     0...80000
Analogue end point [ÂĩS/cm]      20000...100000

Accuracy / deviations
Volumetric flow monitoring
Accuracy (in the measuring range)      with optional factory calibration (available from 2025)    Âą (0,2 % MW + 2 mm/s)
                                                   standard                                                               Âą (0,5 % MW + 1,5 mm/s)
Repeatability                          0,1% MW

Temperature monitoring
Accuracy [K]                           Âą 1
Repeatability [K]                      Âą 0,5

Conductivity monitoring
Accuracy (in the measuring range)        in the range of 100...20000 ÂĩS/cm        Âą10% MW
                                                     in the range of 20000...100000 ÂĩS/cm   Âą20% MW
Repeatability                          Âą 5% MW

Response times
Volumetric flow monitoring
Response time [s]                        < 0.3
Damping process value dAP [s]      0...5

Temperature monitoring
Response time [s]                        < 3; (flow velocity: 0,5m/s)

Conductivity monitoring
Response time [s]                        < 2

Software / programming
Diagnostic functions                     direction of flow detection; liquid detection

Interfaces
Communication interface               IO-Link
Transmission type                        COM3 (230,4 kBaud)
IO-Link revision                           1.1.3
SDCI standard                             IEC 61131-9
Profiles                                      Function class                                       Designation
                                               0x4000                                               Identification and Diagnosis
                                               0x001                                                  BMeasuring and Switching Sensor, floating point, 4 channel
SIO mode                                  yes
Required master port type            A
Process data analogue                 6
Process data binary                     8
Min. process cycle time [ms]          1.9
IO-Link process data (cyclical)        function                                             bit length
                                               totaliser                                             32
                                               flow                                                  32
                                               temperature                                       32
                                               conductivity                                       32
                                               status                                                4
                                               binary switching information                   8
IO-Link functions (acyclical)           direction of flow detection; totaliser; Speicher; operating hours counter; internal temperature; simulation function
Supported DeviceIDs                   Type of operation                                DeviceID
                                              default                                               1798

Operating conditions
Ambient temperature [°C]            -20...65
Storage temperature [°C]             -20...80
Protection                                  IP 67; IP 69


āļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§āļŠāļīāļ™āļ„āđ‰āļē
āļĒāļąāļ‡āđ„āļĄāđˆāļĄāļĩāļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§ āđ€āļ›āđ‡āļ™āļ„āļ™āđāļĢāļāļ—āļĩāđˆāđāļŠāļ”āļ‡āļ„āļ§āļēāļĄāļ„āļīāļ”āđ€āļŦāđ‡āļ™

āļŠāļīāļ™āļ„āđ‰āļēāļ—āļĩāđˆāđ€āļāļĩāđˆāļĒāļ§āļ‚āđ‰āļ­āļ‡

āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ™āļĩāđ‰āļĄāļĩāļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āļ„āļļāļāļāļĩāđ‰ āđ€āļžāļ·āđˆāļ­āđ€āļžāļīāđˆāļĄāļ›āļĢāļ°āļŠāļīāļ—āļ˜āļīāļ āļēāļžāđāļĨāļ°āļ›āļĢāļ°āļŠāļšāļāļēāļĢāļ“āđŒāļ—āļĩāđˆāļ”āļĩāđƒāļ™āļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ‚āļ­āļ‡āļ—āđˆāļēāļ™ āļ—āđˆāļēāļ™āļŠāļēāļĄāļēāļĢāļ–āļ­āđˆāļēāļ™āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄāđ„āļ”āđ‰āļ—āļĩāđˆ āļ™āđ‚āļĒāļšāļēāļĒāļ„āļ§āļēāļĄāđ€āļ›āđ‡āļ™āļŠāđˆāļ§āļ™āļ•āļąāļ§ āđāļĨāļ° āļ™āđ‚āļĒāļšāļēāļĒāļ„āļļāļāļāļĩāđ‰
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļšāļŠāļīāļ™āļ„āđ‰āļē
0/4
āļĨāļšāļ—āļąāđ‰āļ‡āļŦāļĄāļ”
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļš
Powered By MakeWebEasy Logo MakeWebEasy