KT6100

Option name 1
āļˆāļģāļ™āļ§āļ™
āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļŠāļīāļ™āļ„āđ‰āļē

āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī

Product characteristics
Electrical design                              PNP/NPN
Output function                               normally open / normally closed
Communication interface                   IO-Link

Application
Operating principle                          dynamic; (static; bistable parameterisable)

Electrical data
Operating voltage [V]                       12...30 DC
Current consumption [mA]                 30
Protection class                               III
Reverse polarity protection                yes

Outputs
Electrical design                              PNP/NPN
Output function                               normally open / normally closed
Permanent current rating of switching output DC [mA]       150
Short-circuit protection                     yes
Overload protection                         yes

Response times
Response time [ms]                          35

Software / programming
Parameter setting options                  normally open / normally closed; PnP/nPn; statisch / dynamisch / bistabil / Ein- AusschaltverzÃķgerung; Aktivierungs- Operations- Inputfarbe; brightness; SensitivitÃĪt

Interfaces
Communication interface                 IO-Link
Transmission type                          COM2 (38,4 kBaud)
IO-Link revision                             1.1
SDCI standard                               IEC 61131-9
Profiles                                        Smart Sensor: Type 0 Generic Profiled Sensor; Identification and Diagnosis; Fixed Switching Signal Channel
SIO mode                                     yes
Required master port type               A
Process data analogue                    1
Process data binary                        1
Min. process cycle time [ms]             3.5
Supported DeviceIDs                     Type of operation                  DeviceID
                                                default                                 1002

Operating conditions
Ambient temperature [°C]              -20...80
Protection                                   IP 65; IP 67; IP 69K; (on the front)


āļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§āļŠāļīāļ™āļ„āđ‰āļē
āļĒāļąāļ‡āđ„āļĄāđˆāļĄāļĩāļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§ āđ€āļ›āđ‡āļ™āļ„āļ™āđāļĢāļāļ—āļĩāđˆāđāļŠāļ”āļ‡āļ„āļ§āļēāļĄāļ„āļīāļ”āđ€āļŦāđ‡āļ™

āļŠāļīāļ™āļ„āđ‰āļēāļ—āļĩāđˆāđ€āļāļĩāđˆāļĒāļ§āļ‚āđ‰āļ­āļ‡

āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ™āļĩāđ‰āļĄāļĩāļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āļ„āļļāļāļāļĩāđ‰ āđ€āļžāļ·āđˆāļ­āđ€āļžāļīāđˆāļĄāļ›āļĢāļ°āļŠāļīāļ—āļ˜āļīāļ āļēāļžāđāļĨāļ°āļ›āļĢāļ°āļŠāļšāļāļēāļĢāļ“āđŒāļ—āļĩāđˆāļ”āļĩāđƒāļ™āļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ‚āļ­āļ‡āļ—āđˆāļēāļ™ āļ—āđˆāļēāļ™āļŠāļēāļĄāļēāļĢāļ–āļ­āđˆāļēāļ™āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄāđ„āļ”āđ‰āļ—āļĩāđˆ āļ™āđ‚āļĒāļšāļēāļĒāļ„āļ§āļēāļĄāđ€āļ›āđ‡āļ™āļŠāđˆāļ§āļ™āļ•āļąāļ§ āđāļĨāļ° āļ™āđ‚āļĒāļšāļēāļĒāļ„āļļāļāļāļĩāđ‰
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļšāļŠāļīāļ™āļ„āđ‰āļē
0/4
āļĨāļšāļ—āļąāđ‰āļ‡āļŦāļĄāļ”
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļš
Powered By MakeWebEasy Logo MakeWebEasy