Capacitive sensors

KQ6002

Option name 1
āļˆāļģāļ™āļ§āļ™
āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļŠāļīāļ™āļ„āđ‰āļē

āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī

Product characteristics
Electrical design                       PNP
Output function                        normally open / normally closed; (selectable)
Sensing range [mm]                  12
Communication interface            IO-Link
Housing                                  rectangular
Dimensions [mm]                      20 x 14 x 48

Application
Installation                              detection through non-metallic container wall or on bypass pipes
Media                                    dry bulk material; liquids

Electrical data
Operating voltage [V]                10...30 DC
Current consumption [mA]          < 17
Protection class                        III
Reverse polarity protection         yes
Measuring principle                   capacitive

Outputs
Electrical design                       PNP
Output function                        normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V]                        2.5
Permanent current rating of switching output DC [mA]         100
Switching frequency DC [Hz]                                           10
Short-circuit protection                                                  yes
Type of short-circuit protection                                       pulsed
Overload protection                                                      yes

Detection zone
Sensing range [mm]                   12
Real sensing range Sr [mm]         12 Âą 10 %

Accuracy / deviations
Hysteresis [% of Sr]                   1...15
Switch point drift [% of Sr]         -20...20

Interfaces
Communication interface            IO-Link
Transmission type                     COM1 (4,8 kBaud)
IO-Link revision                        1.1
SDCI standard                          IEC 61131-9 CDV
Profiles                                   Smart Sensor
SIO mode                                yes
Min. process cycle time [ms]        100.8
Supported DeviceIDs                 Type of operation        DeviceID
                                            default                       371

Operating conditions
Ambient temperature [°C]           -25...80
Protection                                IP 65; IP 67; IP 69K


āļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§āļŠāļīāļ™āļ„āđ‰āļē
āļĒāļąāļ‡āđ„āļĄāđˆāļĄāļĩāļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§ āđ€āļ›āđ‡āļ™āļ„āļ™āđāļĢāļāļ—āļĩāđˆāđāļŠāļ”āļ‡āļ„āļ§āļēāļĄāļ„āļīāļ”āđ€āļŦāđ‡āļ™

āļŠāļīāļ™āļ„āđ‰āļēāļ—āļĩāđˆāđ€āļāļĩāđˆāļĒāļ§āļ‚āđ‰āļ­āļ‡

āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ™āļĩāđ‰āļĄāļĩāļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āļ„āļļāļāļāļĩāđ‰ āđ€āļžāļ·āđˆāļ­āđ€āļžāļīāđˆāļĄāļ›āļĢāļ°āļŠāļīāļ—āļ˜āļīāļ āļēāļžāđāļĨāļ°āļ›āļĢāļ°āļŠāļšāļāļēāļĢāļ“āđŒāļ—āļĩāđˆāļ”āļĩāđƒāļ™āļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ‚āļ­āļ‡āļ—āđˆāļēāļ™ āļ—āđˆāļēāļ™āļŠāļēāļĄāļēāļĢāļ–āļ­āđˆāļēāļ™āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄāđ„āļ”āđ‰āļ—āļĩāđˆ āļ™āđ‚āļĒāļšāļēāļĒāļ„āļ§āļēāļĄāđ€āļ›āđ‡āļ™āļŠāđˆāļ§āļ™āļ•āļąāļ§ āđāļĨāļ° āļ™āđ‚āļĒāļšāļēāļĒāļ„āļļāļāļāļĩāđ‰
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļšāļŠāļīāļ™āļ„āđ‰āļē
0/4
āļĨāļšāļ—āļąāđ‰āļ‡āļŦāļĄāļ”
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļš
Powered By MakeWebEasy Logo MakeWebEasy