Capacitive sensors

Capacitive sensors

KQ1001

Option name 1
āļˆāļģāļ™āļ§āļ™
āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļŠāļīāļ™āļ„āđ‰āļē

āļ„āļļāļ“āļŠāļĄāļšāļąāļ•āļī

Product characteristics
Electrical design                           PNP/NPN; (parameterisable)
Communication interface                IO-Link
Dimensions [mm]                          250 x 28 x 16.7

Application
Application                                  Continuous level measurement behind non-metallic and non-conductive surfaces
Media                                         dry bulk material; aqueous solutions; oils
Cannot be used for                       highly adhesive media

Electrical data
Operating voltage [V]                    10...30 DC; (IO-Link: 18...30 DC)
Current consumption [mA]              < 50
Protection class                            III
Reverse polarity protection             yes
Max. power-on delay time [ms]        1300

Measuring principle
capacitive                                    Inputs / outputs
Number of inputs and outputs         Number of digital outputs: 3

Outputs
Electrical design                           PNP/NPN; (parameterisable)
Number of digital outputs              3
Permanent current rating of switching output DC [mA]       200
Max. resistance switching output [ÎĐ]                               8
Short-circuit protection                                                yes
Type of short-circuit protection                                     pulsed
Overload protection                                                    yes

Detection zone
Measuring range [mm]                   < 200

Measuring/setting range
Detection range [mm]                      228
Set point SP [%]                             5...95
Reset point rP [%]                           4...94
In steps of [%]                                1

Accuracy / deviations
Repeatability [% of the final value]          2
Offset deviation [% of the final value]      4
Resolution [% of the final value]              1
Linearity deviation [% of the final value]   1

Response times
Response time [ms]                         1300

Software / programming
Parameter setting options                 Damping; hysteresis / window; fault indication; diagnostic function; sensitivity; internal temperature; limitation of measuring range; Adjustable switching delay; zero-point calibration; direction of installation; LEDs can be deactivated

Interfaces
Communication interface                  IO-Link
Transmission type                           COM2 (38,4 kBaud)
IO-Link revision                              1.1
SDCI standard                                IEC 61131-9
Profiles                                         Digital Measuring Sensor Profile, Common Profile
SIO mode                                      yes
Required master port type                A
Process data analogue                     1
Process data binary                         3
Min. process cycle time [ms]              9.6
IO-Link process data (cyclical)           function                             bit length
                                                   process value                     16
                                                   exponent                            8
                                                   device status                       4
                                                   binary switching information   3
IO-Link functions (acyclical)               direction of installation; limitation of sensor elements; sensitivity; minimum recognition threshold; Performance in case of a fault; error delay; Damping; LED mode; switch-on cycle counter; operating hours counter; switching cycles counter; min./max. process value; internal temperature; min./max. internal temperature; diagnostic data for level
Supported DeviceIDs                       Type of operation           DeviceID
                                                   default                         924
Note                                             For further information please see the IODD PDF file under "Downloads"

Operating conditions
Applications                                   DIN EN 60654-1 application class B2
Ambient temperature [°C]                 -20...80
Storage temperature [°C]                  -25...85
Protection                                      IP 65


āļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§āļŠāļīāļ™āļ„āđ‰āļē
āļĒāļąāļ‡āđ„āļĄāđˆāļĄāļĩāļ„āļ°āđāļ™āļ™āđāļĨāļ°āļĢāļĩāļ§āļīāļ§ āđ€āļ›āđ‡āļ™āļ„āļ™āđāļĢāļāļ—āļĩāđˆāđāļŠāļ”āļ‡āļ„āļ§āļēāļĄāļ„āļīāļ”āđ€āļŦāđ‡āļ™

āļŠāļīāļ™āļ„āđ‰āļēāļ—āļĩāđˆāđ€āļāļĩāđˆāļĒāļ§āļ‚āđ‰āļ­āļ‡

āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ™āļĩāđ‰āļĄāļĩāļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āļ„āļļāļāļāļĩāđ‰ āđ€āļžāļ·āđˆāļ­āđ€āļžāļīāđˆāļĄāļ›āļĢāļ°āļŠāļīāļ—āļ˜āļīāļ āļēāļžāđāļĨāļ°āļ›āļĢāļ°āļŠāļšāļāļēāļĢāļ“āđŒāļ—āļĩāđˆāļ”āļĩāđƒāļ™āļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™āđ€āļ§āđ‡āļšāđ„āļ‹āļ•āđŒāļ‚āļ­āļ‡āļ—āđˆāļēāļ™ āļ—āđˆāļēāļ™āļŠāļēāļĄāļēāļĢāļ–āļ­āđˆāļēāļ™āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄāđ„āļ”āđ‰āļ—āļĩāđˆ āļ™āđ‚āļĒāļšāļēāļĒāļ„āļ§āļēāļĄāđ€āļ›āđ‡āļ™āļŠāđˆāļ§āļ™āļ•āļąāļ§ āđāļĨāļ° āļ™āđ‚āļĒāļšāļēāļĒāļ„āļļāļāļāļĩāđ‰
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļšāļŠāļīāļ™āļ„āđ‰āļē
0/4
āļĨāļšāļ—āļąāđ‰āļ‡āļŦāļĄāļ”
āđ€āļ›āļĢāļĩāļĒāļšāđ€āļ—āļĩāļĒāļš
Powered By MakeWebEasy Logo MakeWebEasy